October 5, 2019
project type
ETP
ETP Retrofitting, Environmental Consultancy & Chemical Supply
capacity
1680 m3/day
ETP Retrofitting, Electro-mechanical equipment supply, Testing
wastewater type
Knit-Dying production water
treatment technology
Physico-Chemical followed by Biological MBBR
Diligence with Integrity
We have summarized the basic information on products, solutions and services for this industry clearly structured on specific industry portals.
Design
Parameter
Biochemical Oxygen Demand (BOD)
- INLET: 117 ppm
- OUTLET: 3 ppm
Chemical Oxygen Demand (COD)
- INLET: 290 ppm
- OUTLET: 107 ppm
Total Suspended Solid (TSS)
- INLET: 219 ppm
- OUTLET: 20 ppm
Technology for a
Sustainable Future
Kingsley™ focuses on long term & sustainable future with a reliable technology.